Schneider Electric Square D PGA36060U41A is a 600A molded case circuit breaker designed for solid-state protection with LI (Long-Time and Instantaneous Trip) functions. It operates at 600V with a 35kA interrupting capacity at 480V, supporting 3-phase systems and accommodating wire sizes from 3 x AWG 3/0 to 500 kcmil aluminum or copper. This three-pole breaker features an I-Line style plug-in connection, measures 12.86 in x 8.27 in x 8.05 in (H x W x D), weighs 32 lb, and is rated for temperatures from -13°F to 158°F (-25°C to 70°C). It complies with UL, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2 standards, with certifications from UL, CSA, and NOM. Typical industrial applications include distribution panels and switchboards requiring reliable overcurrent protection in commercial and industrial environments.

Key Features & Specifications
  • Type: Molded case circuit breaker with solid-state trip unit
  • Voltage Rating: 600V AC
  • Current Rating: 600A
  • Dimensions: 12.86 in (326.64 mm) x 8.27 in (210.06 mm) x 8.05 in (204.47 mm) (Height x Width x Depth)
  • Standards: UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2
  • Applications: Distribution panels, switchboards, industrial power systems
  • Switch Type: Molded case
  • Configuration: 3-pole
  • Coil Voltage Maximum: Not applicable (solid-state trip)
  • Temp Rating: -13°F to 158°F (-25°C to 70°C)
  • Shipping Dimensions: 12.86 in x 8.27 in x 8.05 in
  • Phase: 3
  • Voltage: 600V
  • Amperage: 600A
  • AIC rating: 35kA@480V
  • Connection: I-Line Style Plug-In
  • Poles: 3
  • Protection: Solid State
  • Functions: LI - Long-Time and Instantaneous Trip
  • Frame Size: PGA
  • Trip Type: Solid state
  • Panel Type: I-Line
  • Breaker Type: Molded case
  • Control Voltage Minimum: Not applicable
  • Control Voltage Maximum: Not applicable
  • MCM Size: 500 kcmil maximum
  • Metal Type: Not specified
  • Panel Style: I-Line
  • Bus Type: Not specified
  • Fuse Class: Not applicable
  • Insulation Temperature: Not specified
  • Inductance: Not applicable
  • Impedance: Not applicable
  • Barrels: Not applicable
  • Class Rating: Not applicable
  • Diameter: Not applicable
  • Velocity: Not applicable
  • Clip Center: Not applicable
  • Clas: Not applicable
  • Mounting: Plug-in
  • Hz: 50/60 Hz
  • Coil Material: Not applicable
  • Horse Power: Not specified
  • Aux Contacts: Not specified
  • CPT: Not specified
  • Full Load Amps: 600A
  • Dist Voltage: Not specified
  • Bucket Size: Not applicable
  • Bucket Style: Not applicable
  • Bucket Type: Not applicable
  • Full Load Amp Maximum: 600A
  • Full Load Amp Minimum: Not specified
  • Enclosure: Not specified
  • Relay Style: Not applicable
  • Coil Voltage Minimum: Not applicable
  • Wire: 3 x AWG 3/0...500 kcmil
  • Amperage Maximum: 600A
  • Amperage Minimum: Not specified
  • Nema Rating: Not specified
  • Switch Style: Not applicable
  • Wire Size: 3 x AWG 3/0...500 kcmil
  • Certification: UL, CSA, NOM
  • Circuit Breaker Mounting Style: Plug-in
  • Terminal Connection: I-Line
  • Frequency Rating: 50/60 Hz
  • Phase Connection: 3-phase
  • Standards: UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2
  • Compatible Frames: PGA
  • Installation Type: Plug-in
  • Item QTY: 1
  • Nema Starter Size: Not applicable
  • Breaker Frame: PGA
  • Current Rating: 600A
  • Reverse Standoff Voltage: Not applicable
  • Watts: Not specified
  • Peak Pulse Current: Not applicable
  • Breakdown Voltage (MIN VBR@IT ) (V): Not applicable
  • Breakdown Voltage (VBR@IT) (V): Not applicable
  • Polarity: Not applicable
  • Operating Temperature Maximum Celsius: 70°C
  • Max Clamp Voltage: Not applicable
  • On-State Current: Not applicable