Eaton PDG33G0400P3MJ is a Power Defense Series molded case circuit breaker designed for primary overcurrent and ground fault protection in industrial power distribution systems. This three-phase, 400A rated breaker operates at 600VAC with a 35kA interrupting capacity at 480V, utilizing solid-state LSIG trip functions for coordinated protection. The unit measures 109.1 mm depth x 257.1 mm height x 138.9 mm width, weighs 13.2 lb, and features a feed-thru connection configuration with three poles. It complies with UL 489 and CSA standards for industrial control panels and switchboards. Typical applications include main or feeder protection in manufacturing facilities, data centers, and commercial buildings requiring adjustable long-time, short-time, instantaneous, and ground fault trip settings.

Key Features & Specifications
  • Type: Power Defense Series molded case circuit breaker with solid-state trip unit
  • Voltage Rating: 600V AC
  • Current Rating: 400A
  • Dimensions: 109.1 mm x 257.1 mm x 138.9 mm (Length/Depth x Height x Width)
  • Standards: UL 489, CSA C22.2 No. 5
  • Applications: Main or feeder protection in industrial power distribution
  • Switch Type: Molded case
  • Configuration: 3-pole, 3-phase
  • Coil Voltage Maximum: Not applicable (solid-state trip)
  • Temp Rating: 40°C ambient
  • Shipping Dimensions: 12 in x 10 in x 8 in
  • Phase: 3
  • Voltage: 600V AC
  • Amperage: 400A
  • AIC rating: 35kA@480V
  • Connection: Feed-Thru
  • Poles: 3
  • Protection: Solid State LSIG
  • Functions: Long Time, Short Time, Instantaneous, Ground Fault
  • Frame Size: PDG3
  • Trip Type: Electronic (LSIG)
  • Panel Type: Distribution
  • Breaker Type: Molded Case
  • Control Voltage Minimum: Not applicable
  • Control Voltage Maximum: Not applicable
  • MCM Size: 500 kcmil max
  • Metal Type: Copper
  • Panel Style: Standard
  • Bus Type: Copper
  • Fuse Class: Not applicable
  • Insulation Temperature: 105°C
  • Inductance: Not specified
  • Impedance: Not specified
  • Barrels: Not applicable
  • Class Rating: Not applicable
  • Diameter: Not applicable
  • Velocity: Not applicable
  • Clip Center: Not applicable
  • Clas: Not applicable
  • Mounting: Panel mount
  • Hz: 50/60 Hz
  • Coil Material: Not applicable
  • Horse Power: Not specified
  • Aux Contacts: Optional
  • CPT: Not included
  • Full Load Amps: 400A
  • Dist Voltage: 600V
  • Bucket Size: Not applicable
  • Bucket Style: Not applicable
  • Bucket Type: Not applicable
  • Full Load Amp Maximum: 400A
  • Full Load Amp Minimum: 0A
  • Enclosure: Open style
  • Relay Style: Not applicable
  • Coil Voltage Minimum: Not applicable
  • Wire: Copper/Aluminum
  • Amperage Maximum: 400A
  • Amperage Minimum: 0A
  • Nema Rating: 1 (open)
  • Switch Style: Not applicable
  • Wire Size: 500 kcmil max
  • Certification: UL, CSA
  • Circuit Breaker Mounting Style: Fixed
  • Terminal Connection: Feed-thru lugs
  • Frequency Rating: 50/60 Hz
  • Phase Connection: 3-phase
  • Standards: UL 489, CSA C22.2
  • Compatible Frames: PDG3
  • Installation Type: Panelboard
  • Item QTY: 1
  • Nema Starter Size: Not applicable
  • Breaker Frame: PDG3
  • Current Rating: 400A
  • Reverse Standoff Voltage: Not applicable
  • Watts: Not applicable
  • Peak Pulse Current: Not applicable
  • Breakdown Voltage (MIN VBR@IT ) (V): Not applicable
  • Breakdown Voltage (VBR@IT) (V): Not applicable
  • Polarity: Not applicable
  • Operating Temperature Maximum Celsius: 40°C
  • Max Clamp Voltage: Not applicable
  • On-State Current: Not applicable


Product Identification
  • UPC: 786679528198