Schneider Electric MG24138 - Molded Case Breaker 50A 240V 2-Pole

Price
Regular price $172.68
Regular price $5,408.00 Sale price $172.68
Save $5,235.32
/
Condition
  • In stock, ready to ship
  • Backordered, shipping soon
The Schneider Electric MG24138 is a 2-pole molded case circuit breaker designed for thermal-magnetic overcurrent protection in 1-phase systems. It is rated for 240V AC and 50A, with a 10kA interrupting capacity at 240V, and provides long time and instantaneous trip functions for reliable fault clearing. The unit features a compact bolt-on connection design, measuring 3.2 in (81 mm) x 1.4 in (36 mm) x 2.9 in (73 mm) and weighing 0.57 lb, with an operating temperature range of -13 to 158 °F (-25 to 70 °C). It is certified to UL, CSA, EN/IEC, CCC, EAC, GB, and UR standards, ensuring compliance with global industrial safety requirements. This breaker is suitable for use in industrial control panels, distribution boards, and motor control centers requiring dependable branch circuit protection.

Key Features & Specifications
  • Type: Molded Case Circuit Breaker, Thermal Magnetic, Bolt-On
  • Voltage Rating: 240V AC
  • Current Rating: 50A
  • Dimensions: 3.2 in (81 mm) x 1.4 in (36 mm) x 2.9 in (73 mm) (H x W x D)
  • Standards: UL, CSA, EN/IEC, CCC, EAC, GB, UR
  • Applications: Industrial control panels, distribution boards, motor control centers
  • Switch Type: Molded Case
  • Configuration: 2-Pole
  • Coil Voltage Maximum: Not applicable
  • Temp Rating: -13–158 °F (-25–70 °C)
  • Shipping Dimensions: Not specified
  • Phase: 1
  • Voltage: 240V
  • Amperage: 50A
  • AIC rating: 10kA@240V
  • Connection: Bolt-On
  • Poles: 2
  • Protection: Thermal Magnetic
  • Functions: Long Time and Instantaneous Trip
  • Frame Size: Not specified
  • Trip Type: Thermal Magnetic
  • Panel Type: Not specified
  • Breaker Type: Molded Case
  • Control Voltage Minimum: Not applicable
  • Control Voltage Maximum: Not applicable
  • MCM Size: Not applicable
  • Metal Type: Not specified
  • Panel Style: Not specified
  • Bus Type: Not specified
  • Fuse Class: Not applicable
  • Insulation Temperature: Not specified
  • Inductance: Not applicable
  • Impedance: Not applicable
  • Barrels: Not applicable
  • Class Rating: Not applicable
  • Diameter: Not applicable
  • Velocity: Not applicable
  • Clip Center: Not applicable
  • Clas: Not applicable
  • Mounting: Bolt-On
  • Hz: 50/60 Hz (assumed for AC)
  • Coil Material: Not applicable
  • Horse Power: Not specified
  • Aux Contacts: Not specified
  • CPT: Not specified
  • Full Load Amps: Not specified
  • Dist Voltage: Not specified
  • Bucket Size: Not applicable
  • Bucket Style: Not applicable
  • Bucket Type: Not applicable
  • Full Load Amp Maximum: Not specified
  • Full Load Amp Minimum: Not specified
  • Enclosure: Not specified
  • Relay Style: Not applicable
  • Coil Voltage Minimum: Not applicable
  • Wire: Not applicable
  • Amperage Maximum: 50A
  • Amperage Minimum: Not specified
  • Nema Rating: Not specified
  • Switch Style: Molded Case
  • Wire Size: Not specified
  • Certification: UL, CSA, EN/IEC, CCC, EAC, GB, UR
  • Circuit Breaker Mounting Style: Bolt-On
  • Terminal Connection: Bolt-On
  • Frequency Rating: 50/60 Hz
  • Phase Connection: 1-Phase
  • Standards: UL, CSA, EN/IEC, CCC, EAC, GB, UR
  • Compatible Frames: Not specified
  • Installation Type: Panel Mount
  • Item QTY: 1
  • Nema Starter Size: Not applicable
  • Breaker Frame: Not specified
  • Current Rating: 50A
  • Reverse Standoff Voltage: Not applicable
  • Watts: Not applicable
  • Peak Pulse Current: Not applicable
  • Breakdown Voltage (MIN VBR@IT ) (V): Not applicable
  • Breakdown Voltage (VBR@IT) (V): Not applicable
  • Polarity: Not applicable
  • Operating Temperature Maximum Celsius: 70 °C
  • Max Clamp Voltage: Not applicable
  • On-State Current: Not applicable