Key Features & Specifications
- Type: Fuse holder, Class J/R, single-pole, non-fusible
- Voltage Rating: 600V AC/DC
- Current Rating: 400A maximum
- Dimensions: 4.5" H x 2.5" W x 3.0" D
- Standards: UL 4248-1, CSA C22.2 No. 39
- Applications: Industrial power distribution, panelboards, motor control centers
- Switch Type: Non-fusible disconnect
- Configuration: Single-pole
- Coil Voltage Maximum: Not applicable
- Temp Rating: 90°C (194°F) maximum
- Shipping Dimensions: 5.0" H x 3.0" W x 3.5" D
- Phase: Single-phase
- Voltage: 600V
- Amperage: 400A
- AIC rating: 200kA RMS symmetrical at 600V AC
- Connection: Box lug terminals, #14 AWG to 500 MCM
- Poles: 1
- Protection: Overcurrent
- Functions: Fuse accommodation
- Frame Size: 400A
- Trip Type: Not applicable (fuse-dependent)
- Panel Type: Open or enclosed
- Breaker Type: Not applicable
- Control Voltage Minimum: Not applicable
- Control Voltage Maximum: Not applicable
- MCM Size: 500 MCM maximum
- Metal Type: Tin-plated copper
- Panel Style: Standard
- Bus Type: Not applicable
- Fuse Class: J or R
- Insulation Temperature: 90°C
- Inductance: Not specified
- Impedance: Not specified
- Barrels: 1
- Class Rating: 400A
- Diameter: Not applicable
- Velocity: Not applicable
- Clip Center: 2.0 inches
- Clas: J/R
- Mounting: Panel or DIN rail
- Hz: 50/60 Hz
- Coil Material: Not applicable
- Horse Power: Not applicable
- Aux Contacts: Not applicable
- CPT: Not applicable
- Full Load Amps: 400A
- Dist Voltage: 600V
- Bucket Size: Not applicable
- Bucket Style: Not applicable
- Bucket Type: Not applicable
- Full Load Amp Maximum: 400A
- Full Load Amp Minimum: 0A
- Enclosure: Open style
- Relay Style: Not applicable
- Coil Voltage Minimum: Not applicable
- Wire: #14 AWG to 500 MCM
- Amperage Maximum: 400A
- Amperage Minimum: 0A
- Nema Rating: 1 (indoor use)
- Switch Style: Non-fusible
- Wire Size: #14 AWG to 500 MCM
- Certification: UL, CSA
- Circuit Breaker Mounting Style: Not applicable
- Terminal Connection: Box lug
- Frequency Rating: 50/60 Hz
- Phase Connection: Single-phase
- Standards: UL 4248-1, CSA C22.2 No. 39
- Compatible Frames: 400A
- Installation Type: Panel or DIN rail
- Item QTY: 1
- Nema Starter Size: Not applicable
- Breaker Frame: Not applicable
- Current Rating: 400A
- Reverse Standoff Voltage: Not applicable
- Watts: Not applicable
- Peak Pulse Current: Not applicable
- Breakdown Voltage (MIN VBR@IT ) (V): Not applicable
- Breakdown Voltage (VBR@IT) (V): Not applicable
- Polarity: Not applicable
- Operating Temperature Maximum Celsius: 90°C
- Max Clamp Voltage: Not applicable
- On-State Current: Not applicable