Schneider Electric HLA36100U33X - Molded Case Circuit Breaker 100A 600V

Price
Regular price $1,562.87
Regular price Sale price $1,562.87
Save $-1,562.87
/
Condition
  • Low stock - 1 item left
  • Backordered, shipping soon
The Schneider Electric HLA36100U33X is a 3-pole molded case circuit breaker designed for thermal-magnetic protection against overloads and short circuits in industrial power distribution systems. It is rated for 100A at 600VAC, 3-phase, with a high interrupting capacity of 100kA at 480VAC, and features LI (Long-Time and Instantaneous) trip functions for precise overcurrent coordination. This unit measures 6.4 in (163 mm) x 4.09 in (104 mm) x 3.4 in (86 mm) (H x W x D), weighs 8.001 lb, and uses a feed-thru connection with terminals accepting AWG 14 to AWG 3/0 aluminum or copper wire. It complies with UL, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2 standards, making it suitable for panelboards, switchboards, and motor control centers in commercial and industrial environments.

Key Features & Specifications
  • Type: Molded Case Circuit Breaker, Thermal Magnetic, LI (Long-Time and Instantaneous) protection
  • Voltage Rating: 600V
  • Current Rating: 100A
  • Dimensions: 6.4 in (163 mm) x 4.09 in (104 mm) x 3.4 in (86 mm) (Height x Width x Depth)
  • Standards: UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2
  • Applications: Industrial power distribution, panelboards, switchboards, motor control centers
  • Switch Type: Circuit Breaker
  • Configuration: 3-Pole
  • Coil Voltage Maximum: Not applicable (thermal magnetic)
  • Temp Rating: Not specified
  • Shipping Dimensions: Not specified
  • Phase: 3
  • Voltage: 600V
  • Amperage: 100A
  • AIC rating: 100kA@480V
  • Connection: Feed-Thru
  • Poles: 3
  • Protection: Thermal Magnetic
  • Functions: LI - Long-Time and Instantaneous
  • Frame Size: Not specified
  • Trip Type: Thermal Magnetic
  • Panel Type: Not specified
  • Breaker Type: Molded Case
  • Control Voltage Minimum: Not applicable
  • Control Voltage Maximum: Not applicable
  • MCM Size: Not specified
  • Metal Type: Not specified
  • Panel Style: Not specified
  • Bus Type: Not specified
  • Fuse Class: Not applicable
  • Insulation Temperature: Not specified
  • Inductance: Not specified
  • Impedance: Not specified
  • Barrels: Not specified
  • Class Rating: Not specified
  • Diameter: Not specified
  • Velocity: Not specified
  • Clip Center: Not specified
  • Clas: Not specified
  • Mounting: Not specified
  • Hz: Not specified
  • Coil Material: Not applicable
  • Horse Power: Not specified
  • Aux Contacts: Not specified
  • CPT: Not specified
  • Full Load Amps: Not specified
  • Dist Voltage: Not specified
  • Bucket Size: Not specified
  • Bucket Style: Not specified
  • Bucket Type: Not specified
  • Full Load Amp Maximum: Not specified
  • Full Load Amp Minimum: Not specified
  • Enclosure: Not specified
  • Relay Style: Not applicable
  • Coil Voltage Minimum: Not applicable
  • Wire: AWG 14...AWG 3/0 aluminium/copper terminal
  • Amperage Maximum: 100A
  • Amperage Minimum: Not specified
  • Nema Rating: Not specified
  • Switch Style: Not specified
  • Wire Size: AWG 14...AWG 3/0 aluminium/copper terminal
  • Certification: UL, CSA, NOM
  • Circuit Breaker Mounting Style: Not specified
  • Terminal Connection: Feed-Thru
  • Frequency Rating: Not specified
  • Phase Connection: 3-Phase
  • Standards: UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2
  • Compatible Frames: Not specified
  • Installation Type: Not specified
  • Item QTY: Not specified
  • Nema Starter Size: Not specified
  • Breaker Frame: Not specified
  • Current Rating: 100A
  • Reverse Standoff Voltage: Not applicable
  • Watts: Not specified
  • Peak Pulse Current: Not applicable
  • Breakdown Voltage (MIN VBR@IT ) (V): Not applicable
  • Breakdown Voltage (VBR@IT) (V): Not applicable
  • Polarity: Not applicable
  • Operating Temperature Maximum Celsius: Not specified
  • Max Clamp Voltage: Not applicable
  • On-State Current: Not applicable