Square D CVC400LA5 - Molded Case Circuit Breaker 400A 600V
Regular price
$100.73
$100.73
Regular price
$42.40
$42.40
Sale price
$100.73
$100.73
Save $-58.33
/
- Low stock - 3 items left
- Backordered, shipping soon
Key Features & Specifications
- Type: Molded case circuit breaker, thermal-magnetic trip, non-interchangeable trip unit
- Voltage Rating: 600 VAC
- Current Rating: 400 A
- Dimensions: Depth 5.38 in (136.65 mm) x Width 5.64 in (143.26 mm)
- Standards: UL 489, CSA C22.2 No. 5
- Applications: Industrial power distribution, motor control centers, panelboards
- Switch Type: Thermal-magnetic
- Configuration: Fixed mount
- Coil Voltage Maximum: Not applicable (thermal-magnetic)
- Temp Rating: 40°C ambient
- Shipping Dimensions: Depth 5.38 in x Width 5.64 in x Height 3.5 in (approx.)
- Phase: 3
- Voltage: 600 VAC
- Amperage: 400 A
- AIC rating: 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, 25 kAIC at 600 VAC
- Connection: Line and load lugs
- Poles: 3
- Protection: Overcurrent and short-circuit
- Functions: Circuit isolation and protection
- Frame Size: LA
- Trip Type: Thermal-magnetic, fixed
- Panel Type: Not applicable
- Breaker Type: Molded case
- Control Voltage Minimum: Not applicable
- Control Voltate Maximum: Not applicable
- MCM Size: 500 kcmil maximum
- Metal Type: Copper or aluminum
- Panel Style: Not applicable
- Bus Type: Not applicable
- Fuse Class: Not applicable
- Insulation Temperature: 75°C
- Inductance: Not applicable
- Impedance: Not applicable
- Barrels: Not applicable
- Class Rating: Not applicable
- Diameter: Not applicable
- Velocity: Not applicable
- Clip Center: Not applicable
- Clas: Not applicable
- Mounting: Fixed
- Hz: 50/60 Hz
- Coil Material: Not applicable
- Horse Power: Not applicable
- Aux Contacts: Not applicable
- CPT: Not applicable
- Full Load Amps: 400 A
- Dist Voltage: 600 VAC
- Bucket Size: Not applicable
- Bucket Style: Not applicable
- Bucket Type: Not applicable
- Full Load Amp Maximum: 400 A
- Full Load Amp Minimum: 400 A
- Enclosure: Not applicable
- Relay Style: Not applicable
- Coil Voltage Minimum: Not applicable
- Wire: AWG 2/0 to 500 kcmil
- Amperage Maximum: 400 A
- Amperage Minimum: 400 A
- Nema Rating: Not applicable
- Switch Style: Not applicable
- Wire Size: AWG 2/0 to 500 kcmil copper or aluminum
- Certification: UL 489, CSA
- Circuit Breaker Mounting Style: Fixed
- Terminal Connection: Line and load lugs
- Frequency Rating: 50/60 Hz
- Phase Connection: 3-phase
- Standards: UL 489, CSA C22.2 No. 5
- Compatible Frames: LA frame
- Installation Type: Panelboard or switchboard
- Item QTY: 1
- Nema Starter Size: Not applicable
- Breaker Frame: LA
- Current Rating: 400 A
- Reverse Standoff Voltage: Not applicable
- Watts: Not applicable
- Peak Pulse Current: Not applicable
- Breakdown Voltage (MIN VBR@IT ) (V): Not applicable
- Breakdown Voltage (VBR@IT) (V): Not applicable
- Polarity: Not applicable
- Operating Temperature Maximum Celsius: 40°C
- Max Clamp Voltage: Not applicable
- On-State Current: Not applicable
Product Identification
- UPC: 009635929957
- GTIN: 00009635929957