Default product image

Eaton BPHMCP003N - Bus Plug 3A 600V (HMCP Frame)

Price
Regular price $1,489.30
Regular price Sale price $1,489.30
Save $-1,489.30
/
Condition
  • In stock, ready to ship
  • Backordered, shipping soon
Eaton BPHMCP003N Bus Plug is a molded case circuit breaker type bus plug designed for branch circuit protection and disconnection in industrial power distribution systems. It is rated for 600V AC, 3A continuous current, and 65kA interrupting capacity at 480V, providing robust overcurrent protection for sensitive equipment. The unit weighs 40 lb, accommodates 4 AWG wire, and is constructed with a standard design compatible with HMCP frames for seamless integration into existing busway systems. This bus plug complies with UL and NEMA standards, ensuring reliable performance in demanding environments. Typical applications include motor control centers, lighting panels, and machinery power feeds in manufacturing and processing facilities.

Key Features & Specifications
  • Type: Molded case circuit breaker bus plug, standard design, thermal-magnetic trip
  • Voltage Rating: 600V AC
  • Current Rating: 3A
  • AIC Rating: 65kA@480V
  • Phase: 3
  • Wire Size: 4 AWG
  • Weight: 40 lb
  • Compatible Frames: HMCP
  • Standards: UL 489, NEMA AB-1
  • Applications: Branch circuit protection, motor control centers, lighting panels, machinery power feeds
  • Switch Type: Molded case circuit breaker
  • Configuration: 3-pole
  • Coil Voltage Maximum: Not applicable (thermal-magnetic)
  • Temp Rating: 40°C ambient
  • Shipping Dimensions: 12 x 10 x 8 inches (approx.)
  • Voltage: 600V AC
  • Amperage: 3A
  • Connection: Bus plug
  • Poles: 3
  • Protection: Overcurrent and short circuit
  • Functions: Disconnect and protection
  • Frame Size: HMCP
  • Trip Type: Thermal-magnetic
  • Panel Type: Standard
  • Breaker Type: Molded case
  • Control Voltage Minimum: Not applicable
  • Control Voltage Maximum: Not applicable
  • MCM Size: Not applicable
  • Metal Type: Steel enclosure
  • Panel Style: Standard
  • Bus Type: Busway
  • Fuse Class: Not applicable (breaker)
  • Insulation Temperature: 105°C
  • Inductance: Not specified
  • Impedance: Not specified
  • Barrels: Not applicable
  • Class Rating: Not applicable
  • Diameter: Not applicable
  • Velocity: Not applicable
  • Clip Center: Not applicable
  • Clas: Not applicable
  • Mounting: Busway
  • Hz: 50/60 Hz
  • Coil Material: Not applicable
  • Horse Power: Not specified
  • Aux Contacts: Not included
  • CPT: Not included
  • Full Load Amps: 3A
  • Dist Voltage: 600V
  • Bucket Size: Not applicable
  • Bucket Style: Not applicable
  • Bucket Type: Not applicable
  • Full Load Amp Maximum: 3A
  • Full Load Amp Minimum: 3A
  • Enclosure: NEMA 1
  • Relay Style: Not applicable
  • Coil Voltage Minimum: Not applicable
  • Wire: 4 AWG
  • Amperage Maximum: 3A
  • Amperage Minimum: 3A
  • Nema Rating: NEMA 1
  • Switch Style: Molded case
  • Wire Size: 4 AWG
  • Certification: UL 489
  • Circuit Breaker Mounting Style: Fixed
  • Terminal Connection: Lug
  • Frequency Rating: 50/60 Hz
  • Phase Connection: 3-phase
  • Standards: UL 489, NEMA AB-1
  • Compatible Frames: HMCP
  • Installation Type: Busway plug-in
  • Item QTY: 1
  • Nema Starter Size: Not applicable
  • Breaker Frame: HMCP
  • Current Rating: 3A
  • Reverse Standoff Voltage: Not applicable
  • Watts: Not specified
  • Peak Pulse Current: Not applicable
  • Breakdown Voltage (MIN VBR@IT ) (V): Not applicable
  • Breakdown Voltage (VBR@IT) (V): Not applicable
  • Polarity: Not applicable
  • Operating Temperature Maximum Celsius: 40°C
  • Max Clamp Voltage: Not applicable
  • On-State Current: Not applicable


Product Identification
  • UPC: Not available
  • GTIN: Not available