Default product image

Schneider Electric BGL36040 - 3-Pole 40A Molded Case Circuit Breaker

Price
Regular price $744.44
Regular price $1,344.00 Sale price $744.44
Save $599.56
/
Condition
  • Low stock - 8 items left
  • Backordered, shipping soon
Schneider Electric BGL36040 is a 3-pole molded case circuit breaker from the Powerpact family, designed to provide thermal-magnetic protection for electrical distribution equipment and industrial control panels. It is rated for 600V AC, 40A continuous current, and features a 35kA interrupting capacity at 480V, with a 125A/BG frame size and LI (long-time and instantaneous) trip functions. The unit measures 5.4 in (137 mm) x 3.2 in (81 mm) x 3.1 in (80 mm) (H x W x D), weighs 2.93 lb, and uses Everlink lug terminals on both ends for feed-thru connection, accepting wire sizes from 14 AWG to 3/0 AWG (copper or aluminum). It complies with UL 489, CSA C22.2 No 5, EN/IEC 60947-2, NEMA AB1, and other international standards, with certifications including UL, IEC, CCC, EAC, CSA, and NOM, and operates within a temperature range of -13°F to 158°F (-25°C to 70°C). This breaker is suited for industrial applications requiring reliable overcurrent and short-circuit protection in three-phase systems with ABC phase connection.

Key Features & Specifications
  • Type: Molded case circuit breaker, thermal-magnetic protection, standard breaker type
  • Voltage Rating: 600V AC
  • Current Rating: 40A
  • Dimensions: 5.4 in (137 mm) x 3.2 in (81 mm) x 3.1 in (80 mm) (Height x Width x Depth)
  • Standards: UL 489, GB 14048.2, NMX J-266, CSA C22.2 No 5, EN/IEC 60947-2, NEMA AB1, EN/IEC 60947-5-1
  • Applications: Electrical distribution equipment, industrial control panels
  • Switch Type: Standard
  • Configuration: Feed-thru connection
  • Coil Voltage Maximum: Not applicable (thermal-magnetic)
  • Temp Rating: -13°F to 158°F (-25°C to 70°C)
  • Shipping Dimensions: Not specified
  • Phase: 3
  • Voltage: 600V
  • Amperage: 40A
  • AIC rating: 35kA@480V
  • Connection: Feed-Thru
  • Poles: 3
  • Protection: Thermal Magnetic
  • Functions: LI - Long-Time and Instantaneous
  • Frame Size: 125A/BG
  • Trip Type: Thermal-magnetic
  • Panel Type: Electrical Distribution Equipment, Industrial Control Panels
  • Breaker Type: Standard
  • Control Voltage Minimum: Not applicable
  • Control Voltage Maximum: Not applicable
  • MCM Size: Min. Wire Size 14 AWG, 6 AWG Max. Wire Size 2 AWG, 3 AWG
  • Metal Type: Not specified
  • Panel Style: Not specified
  • Bus Type: Not specified
  • Fuse Class: Not applicable
  • Insulation Temperature: Not specified
  • Inductance: Not specified
  • Impedance: Not specified
  • Barrels: Not specified
  • Class Rating: Not specified
  • Diameter: Not specified
  • Velocity: Not specified
  • Clip Center: Not specified
  • Clas: Not specified
  • Mounting: Not specified
  • Hz: Not specified
  • Coil Material: Not applicable
  • Horse Power: Not specified
  • Aux Contacts: Not specified
  • CPT: Not specified
  • Full Load Amps: 40A
  • Dist Voltage: Not specified
  • Bucket Size: Not specified
  • Bucket Style: Not specified
  • Bucket Type: Not specified
  • Full Load Amp Maximum: 40A
  • Full Load Amp Minimum: 40A
  • Enclosure: Not specified
  • Relay Style: Not applicable
  • Coil Voltage Minimum: Not applicable
  • Wire: AWG 6...AWG 2/0 fine stranded aluminium/copper; AWG 14...AWG 3/0 rigid or stranded aluminium/copper
  • Amperage Maximum: 40A
  • Amperage Minimum: 40A
  • Nema Rating: Not specified
  • Switch Style: Standard
  • Wire Size: AWG 6...AWG 2/0 fine stranded aluminium/copper; AWG 14...AWG 3/0 rigid or stranded aluminium/copper
  • Certification: UL, IEC, CCC, EAC, CSA, NOM
  • Circuit Breaker Mounting Style: Not specified
  • Terminal Connection: Everlink Lug Both Ends
  • Frequency Rating: Not specified
  • Phase Connection: ABC
  • Standards: UL 489, GB 14048.2, NMX J-266, CSA C22.2 No 5, EN/IEC 60947-2, NEMA AB1, EN/IEC 60947-5-1
  • Compatible Frames: 125A/BG
  • Installation Type: Not specified
  • Item QTY: Not specified
  • Nema Starter Size: Not applicable
  • Breaker Frame: 125A/BG
  • Current Rating: 40A
  • Reverse Standoff Voltage: Not applicable
  • Watts: Not specified
  • Peak Pulse Current: Not applicable
  • Breakdown Voltage (MIN VBR@IT ) (V): Not applicable
  • Breakdown Voltage (VBR@IT) (V): Not applicable
  • Polarity: Not applicable
  • Operating Temperature Maximum Celsius: 70°C
  • Max Clamp Voltage: Not applicable
  • On-State Current: Not applicable


Product Identification
  • UPC: 606481154098
  • GTIN: 03606480000000