Square D EDB34050SA - 3-Pole 50A Circuit Breaker with Shunt Trip

Price
Regular price $837.55
Regular price $1,424.00 Sale price $837.55
Save $586.45
/
Condition
  • Low stock - 3 items left
  • Backordered, shipping soon
The Square D EDB34050SA is a three-pole molded case circuit breaker designed for overcurrent protection in three-phase electrical systems, featuring a 50A current rating and a 480Y/277V voltage rating. Its thermal-magnetic protection mechanism provides both long-time and instantaneous trip functions, housed within a compact bolt-on unit measuring 143.76 mm H x 99.57 mm W x 102.87 mm D and weighing 4.178 lb. This breaker is certified to cULus and IEC standards and is engineered for an interrupting capacity of 18kA at 480V, with a maximum ambient temperature rating of 40°C (104°F). It is configured with a 120V shunt trip for remote operation and is typically installed in NF-style panelboards, accommodating wire sizes from AWG 12 to 2/0 for aluminum and AWG 14 to 2/0 for copper conductors via its lug terminals.

Key Features & Specifications
  • Type: Three-pole molded case circuit breaker with thermal-magnetic protection and 120V shunt trip
  • Voltage Rating: 480Y/277V AC
  • Current Rating: 50A
  • Dimensions: 143.76 mm H x 99.57 mm W x 102.87 mm D (5.66 in x 3.92 in x 4.05 in)
  • Standards: cULus, IEC
  • Applications: Overcurrent protection in three-phase industrial and commercial NF panelboards
  • Switch Type: Circuit Breaker
  • Configuration: Bolt-On
  • Coil Voltage Maximum: 120V (Shunt Trip)
  • Temp Rating: 40°C (104°F)
  • Shipping Dimensions: Not Specified
  • Phase: 3
  • Voltage: 480Y/277V
  • Amperage: 50A
  • AIC rating: 18kA @ 480V
  • Connection: Bolt-On
  • Poles: 3
  • Protection: Thermal Magnetic
  • Functions: Long-Time and Instantaneous Trip (LI)
  • Frame Size: 125A/EDB
  • Trip Type: Thermal Magnetic
  • Panel Type: NF panelboard
  • Breaker Type: Shunt Trip
  • Control Voltage Minimum: Not Specified
  • Control Voltage Maximum: Not Specified
  • MCM Size: Min. 12 AWG (Al), 14 AWG (Cu); Max. 2 AWG
  • Metal Type: Not Specified
  • Panel Style: Not Specified
  • Bus Type: Not Specified
  • Fuse Class: Not Applicable
  • Insulation Temperature: Not Specified
  • Inductance: Not Specified
  • Impedance: Not Specified
  • Barrels: Not Applicable
  • Class Rating: Not Specified
  • Diameter: Not Applicable
  • Velocity: Not Applicable
  • Clip Center: Not Applicable
  • Class: Molded Case
  • Mounting: Bolt-On
  • Hz: 50/60 Hz (Typical for standards)
  • Coil Material: Not Specified
  • Horse Power: Not Specified
  • Aux Contacts: Not Specified
  • CPT: Not Specified
  • Full Load Amps: Not Specified
  • Dist Voltage: Not Specified
  • Bucket Size: Not Applicable
  • Bucket Style: Not Applicable
  • Bucket Type: Not Applicable
  • Full Load Amp Maximum: Not Specified
  • Full Load Amp Minimum: Not Specified
  • Enclosure: Not Specified
  • Relay Style: Not Applicable
  • Coil Voltage Minimum: Not Specified
  • Wire: Not Specified
  • Amperage Maximum: 50A
  • Amperage Minimum: Not Specified
  • Nema Rating: Not Specified
  • Switch Style: Not Specified
  • Wire Size: AWG 12 to 2/0 (Al), AWG 14 to 2/0 (Cu)
  • Certification: cULus, IEC
  • Circuit Breaker Mounting Style: Bolt-On
  • Terminal Connection: Lug
  • Frequency Rating: Not Specified
  • Phase Connection: 3-Phase
  • Standards: cULus, IEC
  • Compatible Frames: 125A/EDB
  • Installation Type: Panelboard
  • Item QTY: 1
  • Nema Starter Size: Not Applicable
  • Breaker Frame: EDB
  • Current Rating: 50A
  • Reverse Standoff Voltage: Not Applicable
  • Watts: Not Specified
  • Peak Pulse Current: Not Applicable
  • Breakdown Voltage (MIN VBR@IT ) (V): Not Applicable
  • Breakdown Voltage (VBR@IT) (V): Not Applicable
  • Polarity: Not Applicable
  • Operating Temperature Maximum Celsius: 40°C
  • Max Clamp Voltage: Not Applicable
  • On-State Current: Not Applicable


Product Identification
  • UPC: 785901335153
  • GTIN: 00785901335153